Sign in
Discover Guest Blogging Opportunities on Wakamoto: Your Online Diary Platform
Discover Guest Blogging Opportunities on Wakamoto: Your Online Diary Platform
Your Position: Home - Bottles - Microplate
Guest Posts

Microplate

Jun. 10, 2024

Microplate

Flat plate with multiple "wells" used as small test tubes

If you want to learn more, please visit our website 48 well cell culture plates.

Microtiter plates with 96, 384 and wells

A microplate, also known as a microtiter plate, microwell plate or multiwell,[1] is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals.

A microplate typically has 6, 12, 24, 48, 96, 384 or sample wells arranged in a 2:3 rectangular matrix. Some microplates have been manufactured with or wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.[2]

Each well of a microplate typically holds somewhere between tens of nanolitres[3][4][5][6] to several millilitres of liquid. They can also be used to store dry powder or as racks to support glass tube inserts. Wells can be either circular or square. For compound storage applications, square wells with close fitting silicone cap-mats are preferred. Microplates can be stored at low temperatures for long periods, may be heated to increase the rate of solvent evaporation from their wells and can even be heat-sealed with foil or clear film. Microplates with an embedded layer of filter material were developed in the early s by several companies, and today, there are microplates for just about every application in life science research which involves filtration, separation, optical detection, storage, reaction mixing, cell culture and detection of antimicrobial activity.[7]

The enormous growth in studies of whole live cells has led to an entirely new range of microplate products which are "tissue culture treated" especially for this work. The surfaces of these products are modified using an oxygen plasma discharge to make their surfaces more hydrophilic so that it becomes easier for adherent cells to grow on the surface which would otherwise be strongly hydrophobic.

A number of companies have developed robots to specifically handle microplates. These robots may be liquid handlers which aspirate or dispense liquid samples from and to these plates, or "plate movers" which transport them between instruments, plate stackers which store microplates during these processes, plate hotels for longer-term storage, plate washers for processing plates, plate thermal sealers for applying heat seals, de-sealers for removing heat seals, or microplate incubators to ensure constant temperature during testing. Instrument companies have designed plate readers which can detect specific biological, chemical or physical events in samples stored in these plates. A specialized plate reader has also been developed which can perform quality control of microplate well contents, capable of identifying empty wells, filled wells and precipitate.[8]

Manufacture and composition

[

edit

]

The most common manufacturing process is injection molding, using materials such as polystyrene, polypropylene and cyclo-olefin for different temperature and chemical resistance needs. Glass is also a possible material, and vacuum forming can be used with many other plastics such as polycarbonate.

Microplates are manufactured from a variety of materials:

  • Polystyrene (PS) is the most common, and is used for high-clarity optical detection microplates. It can be coloured white by the addition of titanium dioxide for optical absorbance or luminescence detection or black by the addition of carbon for fluorescent biological assays. But, it has poor resistance to organic solvents.
  • Polypropylene (PP) is used for the construction of plates subject to wide changes in temperature, such as storage at &#;80 °C and thermal cycling. It has excellent properties for the long-term storage of novel chemical compounds and high resistance to organic solvents.
  • Cyclo-olefins (COC) are now being used to construct microplates which transmit near-ultraviolet light, allowing applications like protein assays via absorbance measurements at 280 nm. But, COC has a poor resistance to organic solvents & is incompatible with high temperatures.
  • Polycarbonate (PC) is cheap and easy to mould and has been used for disposable microplates for the polymerase chain reaction (PCR) method of DNA amplification.
  • Glass or quartz is also, albeit less commonly & rather expensively, used to construct microplates for special applications that require extreme resistance to organic solvents and/or the surface properties of glass, or the ultraviolet C transmission capability of quartz.

Composite microplates, including filter bottom plates, solid phase extraction (SPE) plates, and even some advanced PCR plate designs, use multiple components and/or materials which are moulded separately and later assembled into a finished product. ELISA plates may now be assembled from twelve separate strips of eight wells, making it easier to only partially use a plate.

Formats and Standardization efforts

[

edit

]

Microplates are produced with the same standardized footprint,[9][10] but using a variety of formats (see table below), materials (see above section), plate heights, numbers of wells, well shapes, and well bottom heights, with some of these characteristics being more varied between manufacturers than others (see below section).

wells volume
(mL) number arrangement 6 2×3 2 &#; 5 12 3×4 2 &#; 4 24 4×6 0.5 &#; 3 48 6×8 0.5 &#; 1.5 96 8×12 0.1 &#; 0.3 384 16×24 0.03 &#; 0.1 32×48 0.005 &#; 0.015; Usage in UHTS (Ultra HTS) 48×72 0.001 &#; 0.005; Usage in UHTS (Ultra HTS).

There are also less common 192- and 768-well plates.[11]

Standardization efforts

[

edit

]

An attempt at standardizing microplates was made by the Society for Biomolecular Sciences with the ANSI-Standards (ANSI/SBS 1-, ANSI/SBS 2-, ANSI/SBS 3-, ANSI/SBS 4-).[12] These standards have been updated to and are now known as the ANSI SLAS standards.

The ANSI SLAS microplate standards define a footprint, and a bottom flange geometry. These footprints & flanges are generally rigorously followed by all microplate manufacterers:

  • Footprint standard[9][10] (127.76 mm × 85.48 mm ± 0.5 mm)
  • Flange standard[13][14]

Corner notch

[

edit

]

Although a corner notch (aka chamfer) is shown at the A1 (top-left) corner in the ANSI SLAS drawings, and many microplates do implement this A1 corner notch, in actuality the "quantity and location of chamfers(s) is optional",[13][14] so in practice the presence or absence of corner notches at additional corners (i.e. the bottom-left) is a proprietary implementation which causes difficulties with accessory cross-compatibility such as with microplate lids that may also implement the matching corner notch.

Well position (standardized)

[

edit

]

The well position is also standardized, but only for 96- , 384-, and -well plates. These are generally well followed by manufacturers:

96-well plates have a 9 mm well-to-well spacing, 384-wells a 4.5 mm spacing, and -wells a 2.25 mm spacing. An notable characteristic is that the well array is symmetrical when the plate is rotated 180˚ around its Z-axis (height axis). Therefore, scientific instruments which use microplates, can accept the plate in one of two rotated orientations - either "correct" or 180˚ rotated.

Other variants like 24-well plates, are not considered in the standard, but there is a de facto standard to implement to 24-wells by apply the same scaling factor as the 384- to 96-well transition, i.e. 24-wells have an 18 mm spacing.

Well shape

[

edit

]

Notably, the shape and diameter of the well is not standardized, and has several proprietary implementations. This causes difficulties with accessory cross-compatibility such as with microplate cap mats.

Wells within the microplate are available in different shapes:

  • Round well
  • Square well

Wells also have different geometries at the bottom of the well:

  • F-Bottom: flat bottom (compatible with through-well optical plate reader measurements)
  • V-Bottom: V-shaped bottom (conical for round wells, square pyramid for square wells; improves aspiration of low liquid volumes)
  • U-Bottom: U-shaped bottom (half sphere; improves aspiration of low liquid volumes)
  • C-Bottom: bottom with minimal rounded edges

Round wells in particular often come in a few diameters:

  • 6.96 mm[17]
  • 8.3 mm

Well Bottom Elevation

[

edit

]

The most recent addition to the ANSI SLAS microplate standards was the inclusion of a well bottom standard. The standard however specifies definitions and test methods only, for the "Microplate Well Bottom Elevation (WBE)", "Well Bottom Elevation Variation (WBEV)", and "Intra-Well Bottom Elevation Variation (IWBEV)", but it does not state a preferred value or limits for those dimensional definitions. Therefore all well bottom heights are currently proprietary implementations without a clear de facto standard. This lack of standardization can cause difficulties with applications such as automated autosampler needle injection.

  • Well Bottom Elevation[18][19]

Standard microplate height

[

edit

]

The height of a standard microplate is also defined, however this is sometimes not followed by manufacturers, even if they follow the footprint and flange standards.

Microplate variants with increased heights

[

edit

]

There are also deep well microplates sometimes called "blocks". Unlike plates of normal height, the ANSI SLAS 2- height standard,[22] does not define a standard height for deep well plates (blocks). Deepwell plates do typically follow a de facto standard height of 44 mm.

Reservoir plates are also commercially available.[23] Reservoir plates have columns of wells (as in 96-well, 24-well, etc. plates) that are fused into single wells, so that they provide additional volume for multichannel pipettes. Like deepwell plates or blocks, they often follow a de facto standard height of 44 mm.

Skirts

[

edit

]

Microplates used for PCR are designed to have a notably thinner wall thickness than standard ANSI/SLAS microplates (to allow for better thermal conduction), and to come in a few different "skirt" types: full-skirt, half-skirt or semi-skirted, and unskirted or no-skirted. The skirt is analogous to the footprint & flange of the ANSI/SLAS standards, so while most full-skirt PCR microplates may be ANSI/SLAS compliant, other deviations such as semi-skirted or others, are not compliant ANSI/SLAS standards.

History

[

edit

]

Additional reading:
Key Differences of Corrugated & Cardboard Boxes
The Pros and Cons of Microwave Popcorn Bags: Is It Worth the Convenience?
How Long Will Cigars Last in a Box?
Are plastic bottles better?
The Benefits of Using Margarine Containers in Your Kitchen
Understanding the Versatility of Stainless Steel Cable Ties
Enhancing Color and Image Quality with Dry Sublimation Paper

The company is the world’s best 24 well cell culture plate supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

A commercial microplate washer

The earliest microplate was created in by a Hungarian, Dr. Gyula Takátsy, who machined six rows of 12 "wells" in Lucite.[11][24][25] Subsequently, Dr. John Louis Sever modified the Hungarian design into a 96-well plate, which he published in .[26] However, common usage of the microplate began in the late s when John Liner introduced a molded version. By there were more than 15 companies producing a wide range of microplates with different features. It was estimated that 125 million microplates were used in alone.[27] The word "Microtiter" is a registered trademark of Thermo Electron OY ( .)

Other trade names for microplates include Viewplate and Unifilter (introduced in the early s by Polyfiltronics and sold by Packard Instrument, which is now part of PerkinElmer).

In , the Society for Biomolecular Screening (SBS), later known as Society for Biomolecular Sciences, began an initiative to create a standard definition of a microplate. A series of standards was proposed in and published by the American National Standards Institute (ANSI) on behalf of the SBS. The standards govern various characteristics of a microplate including well positioning (but not shape, depth, and diameter) as well as plate properties, which allows interoperability between microplates, instrumentation and equipment from different suppliers, and is particularly important in laboratory automation. In , the Society for Biomolecular Sciences merged with the Association for Laboratory Automation (ALA) to form a new organisation, the Society for Laboratory Automation and Screening (SLAS). Henceforth, the microplate standards are known as ANSI SLAS standards.

See also

[

edit

]

References

[

edit

]

  • [1] An article about the invention of the microplate, published in G.I.T. Laboratory Journal (accessed 06/10/10)
  • [2] Dr. Gyula Takátsy, at the Hungarian National Center of Epidemiology website (accessed 06/10/10)
  • [3] Official website publishing Microplate Standards

The microplate: utility in practice

What is a microplate used for?

Microplates are laboratory equipment that consist of a plate with multiple cavities (wells) used as small sample tubes. They are also referred to as microtiter plates or multi-wells and typically come in 6-, 12-, 24-, 48-, 96-, 384- or -well formats with the 96-well layout being the most commonly used. Depending on the well size, they can hold microliter to millilitre volumes of sample. 

Microplates facilitate the preparation, handling, examination, processing, and management of many samples. Today, they are a standard in life science and pharmaceutical research as well as in clinical diagnostics and analytical research. Enzyme-linked immunosorbent assays (ELISA) are one of the most commonly used applications. However, uses are diverse and widespread in the life sciences including sample storage, filtration, separation and mixing, as well as sample detection and quantification. 


A brief history 

Microplates were created in by Hungarian microbiologist Dr. Gyula Takátsy (fig.1), as an influenza epidemic led to a shortage of laboratory equipment. Takátsy needed to find inexpensive solutions to proceed with his clinical tests. He noticed that testing was too expensive in large batches and that a significant increase in throughput could be achieved by placing multiple samples next to each other. Accordingly, he created the first microplate by putting 8 rows of 12 wells (8*12 = 96) together by hand and linked them with a wire loop. This solution enabled him to save time when pipetting.

In the s, his invention gradually gained in popularity and was adopted as standard equipment in biomedical testing by laboratories worldwide.

Widespread usage was further facilitated in the late s as a moulded version was introduced. This decreased the price per unit and increased production capacity. In the following years, microplates were further improved and multiple variants were developed to fit the different needs of the scientific community. 

In the s, the Society for Biomolecular Screening (SBS) started an effort to standardise features and shapes. Features mainly included the number, shape and dimension of wells, as well as properties such as general dimensions and material. In , the American National Standards Institute (ANSI) proposed and published a set of standardised features, which included well diameter, depth and spacing, as well as general dimensions (i.e., 127.76 mm × 85.48 mm).1 

Standardisation led to wider use, particularly benefitting lab automation as well as the production of lab instrumentation. Consequently, the microplate further grew in popularity as an effective support for drug discovery and life science research. It was estimated that around 125,000,000 units were used in alone.2 

In , the SBS and the Association for Laboratory Automation (ALA) merged to form the Society for Laboratory Automation and Screening (SLAS). Since then, microplate standards are referred to as ANSI/SLAS. 

A multitude of choices

Besides the number of wells, microplates come in different materials, colours, and include different well shapes and volume capacities. With plenty of options, it is sometimes hard to pick the optimal one for a specific assay. Here, I will try to summarise the main features while keeping the main focus on spectrophotometric applications.

 

Formats and volumes

Although there are small differences in size and well position for the different types of microplates from different manufacturers, all microtiter plates come with the same footprint dimensions. Wells are usually arranged in a rectangular matrix and typically come in 6-, 12-, 24-, 48-, 96-, 384- and -well formats (fig. 2). A -well layout is also available but is not often used. 

The fill volume for each well depends on the layout. The most used layout is the 96-well format (up to 300 µL/well). Higher density layouts are usually employed for miniaturization purposes. Besides bearing more samples, 384- (up to 100 µL/well), - (up to 15 µL/well), and even -well formats (up to 5 µL/well) reduce reagent volumes and consequently costs (Table 1). 

As a general rule, one-third of the maximum fill volume is the lowest volume recommended for a well to have an efficient and realistic measurement. Hence, you should not go below 100 µL for a standard 96-well microtiter plate.

Half-area 96-well microplates (up to 170 µL/well) are intermediate solutions. These essentially have  the same well size as the 384-well layout while keeping the outer dimensions and well positions of a 96-well. Accordingly, wells are smaller and allow a reduction of up to 50% in sample volume. This format is typically used as an alternative to the 384-well when low volumes are required but automation and throughput are not necessary. 

A similar concept is applied to 384-well layouts in low- or small-volume format (sometimes also referred to as &#;high base&#;). These plates have the same well size as a -well layout with the outer dimensions and well positions of a 384-well plate. Likewise, sample volumes can be reduced by more than 50% when compared to a standard 384-well. In addition to volume, well shape is also affected: while regular 384-well layouts have square-shaped wells, low-volume have round ones. 

Table 1: Comparison of the different fill volume capacities of different layouts.

 

Well number Recommended volume 6 2-5 mL 12 2-4 mL 24 0,5-3 mL 48 0.5-1.5 mL 96 100-300 µL 96 half area 50-170 µL 384 30-100 µL 384 low/small volume 5-25 µL 5-25 µL 1-5 µL

 

In general, higher density formats (i.e., - and -well) cannot be pipetted by hand and a pipetting machine is needed. Manual pipetting is still possible in 384 wells but tedious and usually not recommended. Consequently, one must weigh whether the higher handling costs associated with working with - or -well microplates are counterbalanced by the cost savings achieved by the miniaturization. This is typically the case for high-throughput screening facilities but not for most life science labs.

Plates for ELISA typically come with 96 wells and consist of twelve separate eight-well strips (fig. 3). This architecture simplifies partial use and handling.

 
Materials

Microtiter plates can be manufactured from different materials. The most commonly used are the polymers polycarbonate, polystyrene and cycloolefin. The choice of polymer affects light transmission, autofluorescence, water absorption and gas exchange, and consequently influences use, applications, and assay quality. 

Typically, the most used material for plastic labware is polystyrene. Its transparency makes it ideal for optical detection, absorbance assays (such as ELISA) and microscopy with moderate modification. However, polystyrene does not transmit UV light (< 320 nm) and is hence inappropriate for RNA and DNA quantification. For this purpose, cyclicolefin copolymer (COC) comes with improved ultraviolet light transmission in the range 200 &#; 400 nm and with low autofluorescence (fig. 4).

For optical and microscopy applications as well as high-content screening, glass and quartz are the best possible materials for transparency, autofluorescence and light transmission. However, these materials are very expensive, fragile and are usually not disposable.

Besides optical properties, water absorption and gas exchange play an important role for cell-based applications. In addition, the mechanical properties affect handling, especially by automated systems. Thermal properties can play a role in high-temperature applications (e.g., PCR plates) or when sealers are need.

Polycarbonate and polypropylene are mainly used for PCR plates (fig. 5) and for samples subject to wide changes in temperature (e.g., &#;80°C storage). Besides temperature stability, resistance to numerous solvents and biological inertness are also required for storage purposes.


Colour

Microplates typically come in four colours: clear, black, white, and grey (fig. 6). Depending on the used detection mode, colour may affect signal-to-background ratios and well-to-well cross-talk when very bright and dim samples are adjacent. Accordingly, a suboptimal colour choice can have a negative impact on your data.

Clear (including UV-transparent) microplates are required for absorbance assays as light has to pass through the sample in this detection mode. 
Black microplates (which are darkened by the presence of carbon) partially quench the signal of the sample. This happens because the black colour partially absorbs the light signal coming from the sample. Consequently, these plates are well suited for fluorescence intensity including FRET, and for fluorescence polarization assays. These are usually detection modes with a strong signal yield and the use of the black colour helps to reduce background, auto-fluorescence and well-to-well cross-talk, providing better signal-to-blank ratios.

Black microplates are generally not recommended for luminescence, time-resolved fluorescence (TRF) and TR-FRET assays because these detection modes usually have a comparably low signal yield that would be further quenched by the black colour. White plates, which include titanium dioxide,  are recommended for these assays. The white colour of the well partially reflects the sample signal helping to maximise it. The drawback is that white microplates also increase the blank signal. However, this is usually quite low in luminescent assays. In TRF, the delayed measurement window eliminates the influence of the background.

An intermediate solution between black and white are grey microplates. These are specifically recommended for AlphaScreen® and AlphaLISA® as they reduce cross-talk and background while still providing good signals.

If you would like more details about the influence of plate colour on the measurement results in different detection modes and would like to see data proving the effects, please visit HowTo Note 6: How to choose the best microplate colour for my assay


Microplate well shape

Wells can be either circular or square with the latter having either straight or rounded corners. Square wells contain a larger sample volume and increase the light transmission area compared to round wells. Round wells have a smaller total area and are better suited for shaking. Moreover, as round wells normally do not share a common wall with adjacent wells, they are less affected than square ones by signal cross-talk through the plastic wall of the well.


Microplate well bottom

Well bottoms also come in different shapes: F-, V-, U- and C-bottom (fig. 7). F-bottom (flat) wells provide the best light transmission, are ideal for adherent cell cultures and are suited for bottom-reading assays with plate readers or microscopes.

V-bottom (conical) wells enable maximal volume retrieval of small and precious samples because of their shape. However, the conical shape is disadvantageous for spectrophotometric or imaging applications. Accordingly, V-shaped wells are mainly used for sample storage and precise pipetting.
A rounded well bottom (U-bottom) facilitates mixing, washing, and coating. U-bottom wells enable easy and residue-free pipetting and are typically used for cells in suspension and spheroids.

Curved bottom (C-bottom) wells are a compromise between F-bottom and U-bottom wells. The flat bottom makes them suitable for optical measurements, while the rounded edges facilitate mixing and washing.

 

Well coatings

The surface properties of the well play an important role. Here, the sample and the well material interact with each other. Typically, three main types of microplates are available: non-binding or low-binding, medium-binding, and high-binding. Binding is affected by the physical properties of the material and can be modified by applying different coatings. 

For biochemical spectroscopy and high-throughput screening applications, polystyrene with no coating is typically the material of choice and categorised as medium-binding.

Non-binding plates prevent binding of nucleic acids, proteins and peptides to the surface of the well. Here, a specific coating decreases assay background and improves signal-to-noise.

High-binding microplates are typically used for assays that require the immobilisation of molecules to the surface of the well. One of the best-known uses are ELISA assays. Here, specific coatings and treatments introduce a defined number of hydrophilic groups to facilitate passive adsorption of biomolecules (e.g., antibodies). Medium- and high-binding plates typically differ in the number of available polar groups.

One example of how plate coating can affect biological data was shown by means of a proteasome activity test run with non-binding, medium-binding and high-binding plates. In this study, the researchers obtained different results and showed that the performance of the proteasome assay was affected by the properties of the microplates. Proteasome activity was determined with a fluorescent proteasome substrate, 7-amino-4-methylcoumarin (AMC), a widely used label for this purpose. As the excitation and emission spectra of bound and unbound AMC are different, this allowed the free AMC released by proteolytic cleavage to be easily detected with a fluorescence plate reader. However, standard curves of free AMC showed significant differences among the three plate types. As expected, the high-binding plate gave the lowest signal. Different microplates should therefore be evaluated to determine the best one for the assay as well as the role of any possible plate-specific effects.4 

Different plate-coating may also have a substantial influence on the formation of menisci at the liquid surface which may substantially impact absorbance-based measurements due to a changed path length as explained in the HowTo Note: How to deal with path length and meniscus in microplates.


Cell-based assays

Regular plates cannot be used for cell culture and cell-based assays as they are typically non-sterile. In addition to sterility, specific hydrophilic surface treatments are required to facilitate cell attachment to the bottom of the well. Such hydrophilic treatments are usually referred to as &#;tissue culture-treated&#; or TC-treated. There are also coatings based on extracellular matrix proteins like collagen, fibronectin and laminin, as well as synthetic coatings like with poly-lysines. A cell-repellent surface is typically required for suspension cells, organoids and spheroids. 

Since cellular assays are sometimes evaluated over several hours or days, evaporation from the cell-containing wells can potentially influence the results and ultimately lead to decreased cell viability. Some manufacturers offer plates including an outer moat that can be filled with liquid. This helps to insulate the wells, thereby preventing evaporation especially from edge wells that pose a risk of evaporation.

When running cell-based assays, detecting from the bottom of the well is usually recommended for several reasons. In regular white or black plates, reading from the bottom of the well is not possible and clear bottoms must be used. The walls of the wells can be white or black depending on the assay. The clear bottom can be made of different materials &#; from plastic (polystyrene or cyclicolefin copolymer), up to glass or quartz. Although  detection is significantly better with glass and even more so with quartz compared to plastic, these are also significantly more expensive. Moreover, glass and quartz plates are not disposable and have to be cleaned and autoclaved to sterilise after every use. Hence, one has to decide whether the better performance that comes at a higher cost and with more maintenance, justifies the use of such a plate compared to a cheaper, easy-to-use disposable microplate with a clear plastic bottom.

Use in microplate readers

Microplate readers detect and quantify light signals produced by liquid samples in microplate-based assays. These laboratory instruments are used in the life sciences and pharmaceutical industries to quantify chemical, biological or physical reactions. In addition to biological, cellular, biochemical, pharmaceutical and drug discovery applications, microplate readers are also used in environmental research, and in the food or cosmetics industry.

Microplate readers either come as single- or as multi-mode instruments capable of quantifying samples in different modes such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, TR-FRET, fluorescence polarization and AlphaScreen. Depending on their method of wavelength selection, plate readers can be either monochromator- or filter-based.

Their use typically improves efficiency in laboratory practices and helps to save reagent costs and reduce operational time. For an overview about how microplate readers are used today, please have a look at our application note database.

Despite ANSI/SLAS standards, plates of different manufacturers come with slight variations in dimensions and well positions. This can influence the measured data. Even a small offset in the depth or width of the well position over a line with 24 or 48 wells (for a 384- and -well plate, respectively) may result in measurements no longer being made in the centre of the well but in the worst case on the plastic wall between two samples.

Accordingly, BMG LABTECH readers come with a microplate selection database that includes more than 50 different plate layouts from different manufacturers.

Automated handling

In addition to microplate readers, there are other different instruments that handle or manage microplates. These instruments are specifically used in lab automation. A few examples include liquid handlers and washers used to dispense or remove liquids from and to different plates, robotic arms and conveyor belts to transport plates between instruments, plate stackers to store them for short times and plate hotels or incubators for longer-term storage. In addition, plate sealers and de-sealers apply and remove sealing foils. An example of automated handling can be seen in the following video:

 


Collectively, BMG LABTECH multi-mode readers combine performance with miniaturized assays, compatibility with automated handling options, short measurement times, and result in savings on materials and other resources.

References

1. https://www.slas.org/SLAS/assets/File/public/standards/ANSI_SLAS_1-_FootprintDimensions.pdf

2. Manns, Roy (). Microplate History (2 ed.).
3. https://commons.wikimedia.org/wiki/File:Hepatitis_C_virus_ELISA_Test.jpg

4. Cui Z et al., Anal Biochem. February 1; 446: 44&#;52

Contact us to discuss your requirements of 6 well cell culture plate. Our experienced sales team can help you identify the options that best suit your needs.

Additional reading:
In-Mould Decoration: The Ultimate Guide to Elevating Your Product's Aesthetics
Ultimate Guide to 400ml IML Plastic Containers
Unlocking the Secrets of IML Packaging: Your Ultimate Guide
Top 10oz Butter Tub Brands You Need!
Is ice cream in a cardboard box the new environmentally-friendly trend in packaging?
How do you select bulk buckets with lids?
How to dispose of or recycle Laminated paper

Comments

0 of 2000 characters used

All Comments (0)
Get in Touch

  |   Transportation   |   Toys & Hobbies   |   Tools   |   Timepieces, Jewelry, Eyewear   |   Textiles & Leather Products   |   Telecommunications   |   Sports & Entertainment   |   Shoes & Accessories   |   Service Equipment